Omnidirectional Inductive Powering for Biomedical Implants

In the year 2000, a capsule endoscope was introduced on the market for diagnosis of small bowel diseases. This pill, about one centimeter in diameter, takes images of the gastric track and transmits them wirelessly to the outside world. Since the capsule is battery powered, the limited energy budget...

Full description

Bibliographic Details
Main Authors: Lenaerts, Bert. (Author), Puers, Robert. (Author)
Corporate Author: SpringerLink (Online service)
Format: Electronic
Language:English
Published: Dordrecht : Springer Netherlands, 2009.
Series:Analog Circuits and Signal Processing
Subjects:
Online Access:https://ezaccess.library.uitm.edu.my/login?url=http://dx.doi.org/10.1007/978-1-4020-9075-2
LEADER 02941nam a22004575i 4500
001 5139
003 DE-He213
005 20130725190006.0
007 cr nn 008mamaa
008 100301s2009 ne | s |||| 0|eng d
020 # # |a 9781402090752  |9 978-1-4020-9075-2 
024 7 # |a 10.1007/978-1-4020-9075-2  |2 doi 
050 # 4 |a TK7888.4 
072 # 7 |a TJFC  |2 bicssc 
072 # 7 |a TEC008010  |2 bisacsh 
082 0 4 |a 621.3815  |2 23 
100 1 # |a Lenaerts, Bert.  |e author. 
245 1 0 |a Omnidirectional Inductive Powering for Biomedical Implants  |c by Bert Lenaerts, Robert Puers.  |h [electronic resource] / 
264 # 1 |a Dordrecht :  |b Springer Netherlands,  |c 2009. 
300 # # |b online resource. 
336 # # |a text  |b txt  |2 rdacontent 
337 # # |a computer  |b c  |2 rdamedia 
338 # # |a online resource  |b cr  |2 rdacarrier 
347 # # |a text file  |b PDF  |2 rda 
490 1 # |a Analog Circuits and Signal Processing 
520 # # |a In the year 2000, a capsule endoscope was introduced on the market for diagnosis of small bowel diseases. This pill, about one centimeter in diameter, takes images of the gastric track and transmits them wirelessly to the outside world. Since the capsule is battery powered, the limited energy budget restricts both the amount and the quality of images that can be shot. To resolve this limitation, Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Useful rectifier and inverter topologies are presented, including a class E driver that copes with coil deformations. Special attention is paid to the interaction of the inductive power link with the patient s body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter. 
650 # 0 |a Engineering. 
650 # 0 |a Systems engineering. 
650 # 0 |a Biomedical engineering. 
650 1 4 |a Engineering. 
650 2 4 |a Circuits and Systems. 
650 2 4 |a Biomedical Engineering. 
700 1 # |a Puers, Robert.  |e author. 
710 2 # |a SpringerLink (Online service) 
773 0 # |t Springer eBooks 
776 0 8 |i Printed edition:  |z 9781402090745 
830 # 0 |a Analog Circuits and Signal Processing 
856 4 0 |u https://ezaccess.library.uitm.edu.my/login?url=http://dx.doi.org/10.1007/978-1-4020-9075-2 
912 # # |a ZDB-2-ENG 
950 # # |a Engineering (Springer-11647)